Solid Rocket Motors

Loss of Oxidizer Production Necessitates Emergency Allocation Procedures Gao ID: NSIAD-89-66 December 16, 1988

In response to a congressional request, GAO provided information on the impact of a fire and explosion that destroyed an ammonium perchlorate (AP) plant in Nevada, focusing on: (1) the event's impact on the space program; (2) whether quality and safety problems caused the accident; and (3) who would be responsible for replacing AP production.

GAO found that an advisory group established to resolve potential problems created by the loss of the plant: (1) believed that there was an adequate supply of AP through May 1989; (2) estimated a 14-million-pound production shortfall if the plant failed to resume operation in 1989; (3) did not expect a production shortfall to adversely affect major AP users; and (4) allocated a sufficient supply of AP for space shuttle flights through 1990 and to the Department of Defense for its expendable launch vehicles. GAO also found that: (1) although several agencies are investigating the causes of the accidnt, the plant was fined $36,455 for various safety violations; (2) another firm which produced AP restarted its operations in June 1988, after it paid a fine and corrected safety violations at its facility; and (3) although plans were under way to rebuild the AP plant and to build a new facility at a remote site in Nevada, it was unable to determine the replacement cost or the government's liability.



The Justia Government Accountability Office site republishes public reports retrieved from the U.S. GAO These reports should not be considered official, and do not necessarily reflect the views of Justia.